Which one of the following is not the advantage of HSFG bolt?
Bolts are not subjected to shearing and bearing stresses.
The load transfer is by shearing stresses.
Less stress concentration.
No slip takes place in the joint.
112 practice sets · Page 1 of 6
Which one of the following is not the advantage of HSFG bolt?
Bolts are not subjected to shearing and bearing stresses.
The load transfer is by shearing stresses.
Less stress concentration.
No slip takes place in the joint.
Which one of the following is not limit state of serviceability?
Corrosion
Loss of stability
Fire
Vibration
Which one of the following is not an advantage of bolted connection over welded connection?
Connection can be made easily.
Accommodates minor discrepancies in dimensions.
Alterations in connections can be made easily in the field.
Making joint is noiseless.
Which one of the following is not a variable action?
Wind loads
Earthquake loads
Self-weight
Handling and erection loads
Which one of the following is not a type of bolt?
Turned bolt
High strength friction grip bolt
Hot rolled bolt
Black bolt
Which one of the following is not a correct statement about lug angle connection?
The connection of lug angle to main member shall preferably start in advance of the member to the gusset plate.
Minimum of two bolts are used for connecting lug angle to the gusset plate.
Maximum of five bolts should be used in the connection.
By using lug angle, there will be saving in gusset plate.
When welding is carried out, the length of the weld should be
length shown in drawing + size of weld
length shown in drawing + 2 × size of weld
length shown in drawing + 4 × size of weld
length shown in drawing
When the two columns to be spliced are of slightly different size
milled ends are provided
filler plates are used
bearing plates are used
milled end and bearing plated are used
Weldability of steel is enhanced by alloying it with
carbon
sulphur
chrome
nickel
Unit weight of G.I. sheets is
65 N/m2
85 N/m2
105 N/m2
125 N/m2
Under fatigue stresses, which one of the following joint fails earlier?
black bolted
turned bolted.
HSFG bolted
welded.
To connect members subjected to dynamic loads which one of the following type of bolts is preferable?
black bolts
turned bolts
HSFG bolts
both b and c
To account for weight of electrical fixtures like lights and fans, on lower panel points of trusses additional occasional load to be considered is
5–10 kN
10–15 kN
15–20 kN
20–30 kN
Thickness of battens shall not be less than.....................of the distance between the innermost connecting lines of bolts.
30-Jan
Jan-40
Jan-50
Jan-60
The yield strength and ultimate strength of M20 bolts are
20 N/mm2 and 28 N/mm2
200 N/mm2 and 280 N/mm2
200 N/mm2 and 400 N/mm2
240 N/mm2 and 400 N/mm2
The successful introduction of..............bolts resulted into replacement of rivets.
black bolt
turned bolt
HSFG bolts
all of the above
The slenderness ratio of lacing bars should not exceed
105
125
145
160
The roof covering weight including A.C. sheets, laps, connector etc. may be taken as
100–125 N/m2
125–150 N/m2
150–170 N/m2
170–200 N/m2
The number of battens should be such that the member is divided into not less than............bays.
3
4
5
6
The most economical section for a compression member is
rectangular
I-shaped
circular
hollow circular