Weepholes should be what size in diameter?
1/8 inch
1/4 inch
1/2 inch
3/4 inch
277 practice sets · Page 7 of 14
Weepholes should be what size in diameter?
1/8 inch
1/4 inch
1/2 inch
3/4 inch
water diverter used on the high side of a chimney, usually metal, is
Counter flashing
Saddle flashing
Standard flashing
Simple flashing
Vertical front wall flashing should extend up the wall a minimum of how many inches?
3
4
5
6
vapor retardant base sheet should be installed when the outside winter temperature is how many degrees or less?
32
40
45
50
U-Value of 0.17 will equal R Value.
6.25
5.88
5.56
5.26
Usually the maximum layers of shingles a roof can support is
2
3
4
9
Use a box nail to install a 24-inch tapersplit shake on a new roof.
6d
5d
4d
3d
Type IV asphalt softens at how many degrees?
210
225
158
135
Type IV asphalt on smooth surfaces lacks which of the following?
Viscosity
Self-healing properties
Good adhesion in cold weather
Good melt rates
Type IV asphalt has a softening temperature of
205 to 225 degrees
200 to 220 degrees
158 to 176 degrees
135 to 151 degrees
Type IV (special steep) asphalt softens at degrees Fahrenheit.
135 to 151
158 to 176
180 to 205
205 to 225
Two joints of shakes should never line up in how many courses?
1
2
3
4
Trimming of a sharp valley corner is known as
Good to do if the boss is watching
Dubbing
Clipping
Expensive
To prevent chimneys from leaking the contractor should apply which of the following?
generous amount of roofing cement
small amount of roofing cement
flue collar
flue cap
To pass the test, the weight of the test-cut components must be within what percent plus or minus of the speciied requirements?
10
15
25
50
To pass the test, the weight of the test-cut components must be within what percent plus or minus of the specified requirements?
10
15
20
25
To install shingles in a woven valley
Trim the shingles two inches back from the valley centerline
The felt underlayment must be doubled in the valley area
Extend the shingles across the valley
Shingle end joints should be at least 12 inches from valley centerline
To ensure a snug fit it is good practice to
Order pre-cut materials
Hire a professional carpenter
Miter the rake tiles
Use lead soakers
To construct an open valley, shingles at the upper end of an open valley should be inches apart at the centerline.
3
6
9
12
To allow for expansion and contraction, install a loose 4-inch glass fiber strip covered with?
Type III asphalt
16-inch Tedlar sheet
Concrete or mortar barrier
Lead slip sheet