In an Anderson bridge, the unknown inductance is measured in terms of
known inductance and resistance
known capacitance and resistance
known resistance
known inductance
108 practice sets · Page 5 of 6
In an Anderson bridge, the unknown inductance is measured in terms of
known inductance and resistance
known capacitance and resistance
known resistance
known inductance
In an AC. co-ordinate potentiometer, the currents in the phase and quadrature potentiometer are adjusted to be
out of phase by 90°
out of phase by 60°
out of phase by 30°
out of phase by 0°
In a Weston synchronoscope, the fixed coils are connected across
bus-bars
incoming alternator
a lamp
none of the above
In a Weston frequency meter, the magnetic axes of the two fixed coils are
parallel
perpendicular
inclined at 60°
inclined at 120°
In a vibrating reed frequency meter the natural frequencies of two adjacent reeds have a difference of
0.1 Hz
0.25 Hz
0.5 Hz
1.5 Hz
In a single phase power factor meter the phase difference between the currents in the two pressure coils is
exactly 0°
approximately 0°
exactly 90°
approximately 90°
In a Schering bridge the potential of the detector above earth potential is
a few volts only
1 kV
5 kV
10 kV
In a portable instrument, the controlling torque is provided by
spring
gravity
eddy currents
all of the above
In a meggar controlling torque is provided by
spring
gravity
coil
eddy current
In a low power factor wattmeter the pressure coil is connected
to the supply side of the current coil
to the load side of the current coil
in any of the two meters at connection
none of the above
In a low power factor wattmeter the compensating coil is connected
in series with current coil
in parallel with current coil
in series with pressure coil
in parallel with pressure coil
In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at
0°
60°
90°
120°
In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was
unity
0.8 lagging
0.8 leading
zero
In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be
unity
0.5
0.3
zero
If the current in a capacitor leads the voltage by 80°, the loss angle of the capacitor is
10°
80°
120°
170°
If an instrument has cramped scale for larger values, then it follows
square law
logarithmic law
uniform law
none of the above
If an inductance is connected in one arm of bridge and resistances in the remaining three arms
the bridge can always be balanced
the bridge cannot be balanced
the bridge can be balanced if the resistances have some specific values
For measuring current at high frequency we should use
moving iron instrument
electrostatic instrument
thermocouple instrument
none of the above
For measuring a very high resistance we should use
Kelvins double bridge
Wheat stone bridge
Meggar
None of the above
For measurements on high voltage capacitors, the suitable bridge is
Wein bridge
Modified De Santys bridge
Schering bridge
Any of the above